Laboratory & Quality Control

Tested. Verified. Trusted.

A well-equipped in-house laboratory conducting routine testing of every raw material and concrete mix β€” governed by a Quality Management System based on ISO 9001:2015.

Overview

Quality, Controlled In-House

Safe Mix operates a well-equipped in-house laboratory conducting routine tests on raw materials and on every concrete mix, governed by a Quality Management System based on ISO 9001:2015.

Managed by the Technical Manager, all QC personnel are trained and qualified, with periodic training on codes and standards.

Method 01
In-House Testing
Routine daily and weekly tests on raw materials and final product within the Safe Mix laboratory.
Method 02
Independent Testing
Periodic verification through an approved external EIAC-accredited laboratory.
The QC Team β€” Led by the Technical Manager
01Lab Engineers
02QC Engineer
03Lab Technicians
04Lab Assistants
05Site Supervisors
Testing Matrix

In-House & External Testing.

Every raw material and the final product is tested to recognised international standards β€” routine checks in-house, full chemical & durability analysis at an accredited external laboratory.

Ordinary Portland Cement
ExternalEvery 6 MonthsBS EN 196
Chemical
LOISiOβ‚‚Alβ‚‚O₃Feβ‚‚O₃CaOMgOSO₃ClC₃A Β· Cβ‚‚S Β· C₃S Β· Cβ‚„AFTotal Alkalis
Physical
BlaineSoundnessConsistencySetting TimeCompressive Strength
GGBS Slag
ExternalEvery 6 MonthsBS EN 196
Chemical
LOISiOβ‚‚CaOMgOSO₃Sulfide SChemical ModulusCaO/SiOβ‚‚
Physical
BlaineSoundnessSetting TimeMoistureCompressive Strength
Silica Fume
ExternalEvery 6 MonthsASTM C1240
Chemical
SiOβ‚‚CarbonFeβ‚‚O₃Alkali Naβ‚‚O eq.ClSO₃LOI
Physical
Moisture45Β΅m ResiduePozzolanic IndexCompressive StrengthBulk Density
Aggregates
In-House + External
In-House Β· Daily / Weekly
Moisture ContentSieve AnalysisSpecific GravityWater AbsorptionFlakinessElongationBulk Density
External Β· Every 6 Months
Organic ImpuritiesClay LumpsSoundnessACVAIVLA AbrasionChloride / SulphateASR
Admixtures
In-House + ExternalASTM C494 / EN 934-2
External Β· Every 6 Months
Chemical PropertiesPhysical Properties
In-House Β· Per Delivery
Specific Gravity (each delivery)
Hardened Concrete β€” Durability
External
Durability Tests
Water Absorption β€” BS 1881-122Water Permeability β€” DIN 1048-5ISAT β€” BS 1881-208Acid Soluble Sulphate β€” BS 1881-124Acid Soluble Chloride β€” BS 1881-124
Quality Control

Block Testing & Equipment Calibration.

Concrete Block Tests
Visual Checking
Continuous
Dimension Check (LΓ—BΓ—H)
Daily
Density & Compressive Strength
Daily
Apparent Density (Thermal)
Daily
Drying Shrinkage
Quarterly
Thermal Conductivity
Annually
Calibration Evidence
Pass
Certificate
Concrete Batching Plant
Cert No.GCLC/MINS40710.01/2026
AssetPlant-03 Β· Jebel Ali
Calibrated14 Jan 2026
Due13 Jul 2026
Issued ByGCLC Β· EIAC-accredited
Mix Design Process

From Specification To Verified Mix.

1
Study Specs
Analyze raw materials, required strength, durability & cementitious ratios.
2
Lab Trials
Laboratory trials on the proposed mix design.
3
Plant Trial
Plant trial on proportions from the laboratory.
4
Fine-Tune
Adjustments return to the lab for revision.
5
Records
Batched concrete logged with delivery note.
Certified & Accredited
ISO 9001
Quality
ISO 14001
Environment
ISO 45001
Health & Safety
DCL
Product Conformity
GCLC
EIAC Calibration
EIAC
External Testing